mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Removal and Replacement|Page 4711 > < Removal and Replacement|Page 4709
Page 9
background image

1. Position the recirculation-air door (5) into the air inlet housing (1).

CAUTION:  Make sure that the recirculation-air door pivot shaft is properly seated in the pivot holes located in the two halves of the air
inlet housing.

NOTE:  If the seal on the air door is deformed or damaged, the air door must be replaced.

2. Install the four screws (4) that secure the two halves of the air inlet housing together. Tighten the screws to 2 N.m (17 in. lbs.).
3. Install the blower motor resistor onto the air inlet housing.
4. Install the recirculation door actuator onto the air inlet housing.
5. Install the air inlet housing onto the HVAC housing.

HVAC HOUSING

CAUTION:  Be certain to adjust the refrigerant oil level when servicing the A/C refrigerant system. Failure to properly adjust the refrigerant
oil level will prevent the A/C system from operating as designed and can cause serious A/C compressor damage.

NOTE:

-

When replacing multiple A/C system components, refer to the Refrigerant Oil Capacities chart to determine how much oil should be added to the 
refrigerant system.

-

If the A/C evaporator is being replaced, add 60 milliliters (2 fluid ounces) of refrigerant oil to the refrigerant system. Use only refrigerant oil of
the type recommended for the A/C compressor in the vehicle.

Removal and Replacement|Page 4711 > < Removal and Replacement|Page 4709