1. Disconnect and isolate the negative battery cable.
2. Remove the three screws (1) that secure the panel door actuator (2) to the driver side end of the HVAC housing (3).
3. Disconnect the HVAC wire harness connector (4) from the panel door actuator.
4. Remove the panel door actuator from the HVAC housing.

INSTALLATION

NOTE: This heater-A/C system is equipped with two mode door actuators. One for the floor/defrost-air door and one for the panel-air door.

FLOOR/DEFROST DOOR ACTUATOR

1. Position the floor/defrost door actuator (1) onto the driver side end of the HVAC housing (2). If necessary, rotate the actuator slightly to align the

splines on the actuator output shaft (3) with those on the floor/defrost door pivot shaft (4).