mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Removal and Replacement|Page 5129 > < Removal and Replacement|Page 5127
Page 11
background image

11. Position the floor distribution duct (2) onto the bottom of the HVAC housing (3).
12. Install the screws (1) that secure the floor distribution duct to the HVAC housing. Tighten the screws to 2 N.m (17 in. lbs.).

NOTE: If the seal on the air door is deformed or dam- aged, the air door must be replaced.

13. Align the pivot shaft of the panel-air door (1) with the pivot hole in the top of the HVAC housing (2) and install the panel-air door into the

housing.

Removal and Replacement|Page 5129 > < Removal and Replacement|Page 5127