Transmission Control System Relay: Description and Operation
Service Information - 45RFE/545RFE

RELAY - TRANSMISSION CONTROL 

DESCRIPTION 
The relay is supplied fused B+ voltage, energized by the TCM, and is used to supply power to the solenoid pack when the transmission is in normal
operating mode.

OPERATION 
When the relay is off, no power is supplied to the solenoid pack and the transmission is in limp-in mode. After a controller reset, the TCM energizes the
relay. Prior to this, the TCM verifies that the contacts are open by checking for no voltage at the switched battery terminals. After this is verified, the
voltage at the solenoid pack pressure switches is checked. After the relay is energized, the TCM monitors the terminals to verify that the voltage is 
greater than 3 volts.