mitsubishi Workshop Repair Guides

Mitsubishi Workshop Service and Repair Manuals

Transfer Case - NV233 - M/T|Page 4053 > < Transfer Case - NV233 - M/T|Page 4051
Page 2
background image

encoder_4LO_min Volts has been reached.

^

4HI TARGET REGION - The position shall be considered 4HI if the voltage is greater than or equal to encoder_4HI_min Volts and it is also less
than or equal to encoder_4HI_max Volts.

^

NEUTRAL TARGET REGION - The position shall be considered NEUTRAL if the voltage is greater than or equal to encoder_Neutral_min
Volts and it is also less than or equal to encoder_Neutral_max Volts.

^

2WD TARGET REGION - The position shall be considered 2WD if the voltage is greater than or equal to encoder_2WD_min Volts and it is also
less than or equal to encoder_2WD_max Volts.

^

2WD SHIFT LIMIT - During Phase 2 and Phase 3 shifting, shifts may become unidirectional when a voltage is greater than or equal to
encoder_2WD_min Volts has been reached.

^

The mode sensor position will be considered invalid by the FCM if the voltage is greater than or equal to encoder_High_Range_Limit Volts or if it
is less than or equal to encoder_Low_Range_Limit Volts

Refer to MODE SENSOR VOLTAGES <NV233> table for the mode sensor voltages.

MODE SENSOR VOLTAGES <NV233> (Part 1)

MODE SENSOR VOLTAGES <NV233> (Part 2)

Transfer Case - NV233 - M/T|Page 4053 > < Transfer Case - NV233 - M/T|Page 4051