Van Wagon L4-2350cc 2.4L SOHC (1990)
Inhibitor Switch: Service and Repair
Fig. 9 Adjusting Neutral Safety Switch
1.
Place sector lever in Neutral position.
2.
Disconnect switch electrical connector.
3.
Remove control lever retainer and lever.
4.
Remove switch attaching bolts, then the switch.
5.
Reverse procedure to install, the adjust as follows:
a. Ensure manual control lever is in Neutral position.
b. Align positioning boss on switch with manual control lever, Fig. 9.
c. Torque switch attaching bolts to 3-5 ft. lbs.