200SX SE-R L4-1998cc 2.0L DOHC MFI (SR20DE) (1998)
Battery: Testing and Inspection
Specific Gravity Check
1. Read hydrometer and thermometer indications at eye level.
^ When electrolyte level is too low, tilt battery case to raise it for easy measurement.