240SX L4-2.4L (KA24DE) (1993)
Actuator: Testing and Inspection
Hydraulic Assembly
Fig. 212 Actuator Motor Ground Circuit Check
ACTUATOR MOTOR GROUND
When performing actuator motor ground circuit check, refer to Fig. 212. Resistance between both terminals should be zero ohms.