280ZX L6-2753cc 2.8L SOHC (L28E) (1982)
Blower Motor Resistor: Service and Repair
NOTE: Blower motor speeds are controlled by a control amplifier unit which contains an integral resistor.
1.
Disconnect battery ground cable.
2.
Remove right hand lower dash panel and floor nozzle.
3.
Disconnect wiring harness connector and remove control amplifier from blower motor.
4.
Reverse procedure to install.