300ZX V6-2960cc DOHC (VG30DE) (1990)
Auxiliary Air Valve (Idle Speed): Mechanical Specifications
ACCELERATOR CABLE ADJUSTING NUT
Torque value ............................................................................................................................................................................... 5.8 - 7.2 ft-lb (8 - 10 Nm)
AIR REGULATOR
Torque Value ............................................................................................................................................................................... 3.6 - 4.3 ft-lb (5 - 6 N-m)
FUEL INJECTOR
Torque value ........................................................................................................................................................................... 1.8 - 2.4 ft-lb (2.5 - 3.2 Nm)
FUEL LINE CLAMP
Torque value .............................................................................................................................................................................. 0.7 - 1.1 ft-lb (1 - 1.5 Nm)
FUEL FILLER NECK TO TANK
Torque value ........................................................................................................................................................................... 2.9 - 3.3 ft-lb (3.9 - 4.4 Nm)
FUEL PUMP MOUNTING
Torque value
2 + 2 ......................................................................................................................................................................................... 1.8 - 2 ft-lb (2.5 - 2.6 Nm)
2 Seater ..................................................................................................................................................................................... 1.4 - 1.9 ft-lb (2 - 2.5 Nm)
FUEL TANK MOUNTING
Torque value ............................................................................................................................................................................... 23 - 31 ft-lb (31 - 42 Nm)
INTAKE COLLECTOR
Torque value ............................................................................................................................................................................... 12 - 15 ft-lb (16 - 21 Nm)
INTAKE MANIFOLD
Torque value
Bolts
1st step ....................................................................................................................................................................................... 2.2 - 3.6 ft-lb (3 - 5 Nm)
2nd step ................................................................................................................................................................................... 12 - 14 ft-lb (16 - 20 Nm)
Nuts
1st step ....................................................................................................................................................................................... 2.2 - 3.6 ft-lb (3 - 5 Nm)
2nd step ................................................................................................................................................................................... 17 - 20 ft-lb (24 - 27 Nm)
THROTTLE CHAMBER
Torque value
1st step .......................................................................................................................................................................................... 6.5 - 8 ft-lb (9 - 11 Nm)
2nd step ..................................................................................................................................................................................... 13 - 16 ft-lb (18 - 22 Nm)
TURBOCHARGER MOUNTING
Torque value ............................................................................................................................................................................... 32 - 40 ft-lb (43 - 54 Nm)
TURBOCHARGER COOLANT TUBES
Torque value ............................................................................................................................................................................... 11 - 14 ft-lb (15 - 20 Nm)
TURBOCHARGER AIR INLET
Torque value ................................................................................................................................................................................... 4.6 - 6.1 (6.3 - 8.3 Nm)
TURBOCHARGER OIL DELIVERY TUBE
Torque value ............................................................................................................................................................................... 11 - 13 ft-lb (15 - 18 Nm)
TURBOCHARGER OIL DRAIN TUBE
Torque value ............................................................................................................................................................................... 16 - 21 ft-lb (12 - 15 Nm)