nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Component Tests and General Diagnostics|Page 3817 > < Component Tests and General Diagnostics|Page 3815
Page 2
background image

5. Remove fuel feed hose (with damper) (1) from fuel sub-tube (2) and harness bracket (3).

-: Engine front

NOTE: There is no fuel return route.

CAUTION: 
-

While hoses are disconnected, plug them to prevent fuel from draining.

-

Do not separate fuel damper and fuel feed hose.

6. When separating fuel feed hose (with damper) and centralized under-floor piping connection, disconnect quick connector as follows:

a. Remove quick connector cap (2) from quick connector connection on right member side.
b. Disconnect fuel feed hose (with damper) (1) from bracket hose clamp.
c. Disconnect quick connector from centralized under-floor piping as follows:

CAUTION: Disconnect quick connector by using quick connector release [SST: - (J-45488)], not by picking out retainer tabs.

i.

With the sleeve side of quick connector release facing quick connector, install quick connector release onto centralized under-floor piping.

ii.

Insert quick connector release into quick connector until sleeve contacts and goes no further. Hold quick connector release on that position.

CAUTION: Inserting quick connector release hard will not disconnect quick connector. Hold quick connector release where it
contacts and goes no further.

iii.

Draw and pull out quick connector straight from centralized under-floor piping.

CAUTION: 
- Pull quick connector holding "A" position as shown in the figure.

Component Tests and General Diagnostics|Page 3817 > < Component Tests and General Diagnostics|Page 3815