Altima L4-2.5L (QR25DE) Hybrid (2007)
PERSONAL PROTECTIVE EQUIPMENT
When engaged in operations such as removal and installation related to high voltage equipment, use personal protective equipment to avoid death or
serious personal injury from electric shock.
INSULATION RESISTANCE CHECK TOOL
When making an insulation resistance check, the tester which can measure the resistance with applying 1000 V is necessary.
PERSONAL PROTECTIVE EQUIPMENT CHECK
Inspect the personal protective equipment before use.
WARNING: Personal protective equipment must not have abnormalities such as scratches and tears which will influence the insulation
performance.
INSULATION RESISTANCE CHECK OF INSULATION GLOVES
Check before starting work
Before wearing insulated gloves, check that gloves are not cracked, ruptured, torn, or damaged by inflating.