Altima L4-2.5L (QR25DE) Hybrid (2007)
Seals and Gaskets: Customer Interest
Hybrid Systems - Coolant Leaks
Classification: AT10-002
Reference: NTB10-070
Date: May 19, 2010
ALTIMA HYBRID; COOLANT LEAK
APPLIED VEHICLE: 2007 - 2010 Altima Hybrid (L32HV)
IF YOU CONFIRM:
Coolant is leaking from the eCVT Sump Pump Plate area.
^ DTC P0A93-346 (Inverter Cooling System Performance) and / or P3216-181 (Reactor Temperature Sensor Circuit Low) may be found stored in
CONSULT III / HYBRID SYSTEM.
ACTION:
Re-seal the eCVT sump pump plate.
For repair procedure, refer to SERVICE PROCEDURE shown below.
Do NOT replace the eCVT assembly for this incident, if it should occur.
WARNING:
This vehicle has a High Voltage system. Review "Precautions For High-Voltage System" in the GI section of the appropriate Electronic Service Manual
(ESM).
IMPORTANT:
Follow all cautions, warnings, and notes in the ESM when working on an Altima Hybrid vehicle. You MUST have completed "Altima Hybrid New
Technology Introduction" Service Training before working on this vehicle.
IMPORTANT:
The purpose of ACTION (above) is to give you a quick idea of the work you will be performing. You MUST closely follow the entire SERVICE
PROCEDURE as it contains information that is essential to successfully completing this repair.
PARTS INFORMATION