The main fuse for the high-voltage circuit is provided inside of the service plug assembly.

NOTE:  After the service, please do not start the system until the service plug is connected.

HV BATTERY AND DC/DC CONVERTER COOLING SYSTEM

HV Battery Cooling System

-

A dedicated cooling system is used to ensure that the HV battery performs properly, despite it generating significant heat during the repetitive
charge and discharge cycles.
This cooling system employs an air-cooling method, which uses the dedicated cooling fan to cool the HV battery with air from inside the cabin.

-

The air from inside the cabin, which is introduced through the intake duct located on the rear package tray trim, flows downwards through the
battery module, reducing the temperature of the battery module, and is emitted from the vehicle through the exhaust duct.

-

The hybrid vehicle control ECU controls the operation of the cooling fan for the HV battery. The hybrid vehicle control ECU receives the signals
from the battery temperature sensor, which is built into the HV battery,via the battery smart unit. Then, it controls the cooling fan in order to
control the battery module temperature appropriately.