Altima L4-2.5L (QR25DE) Hybrid (2007)
Component Parts Location
Component
HIGH-PRESSURE FLEXIBLE HOSE
Removal and Installation for High-Pressure Flexible Hose
REMOVAL
1. Disconnect the high voltage electrical system.
CAUTION:
-
Wear electrically insulated gloves and pull out the service plug grip before inspection as procedures may require disconnecting high
voltage connectors. Be sure to carry the removed service plug grip because other workers may install it by mistake.
-
Never touch the high voltage connectors or terminals for 10 minutes after the service plug grip is removed.
2. Disconnect the 12-volt battery negative terminal.
3. Remove the engine air cleaner front air duct.
4. Discharge the refrigerant. Refer to "HFC-134a (R-134a) Service Procedure".
5. Disconnect the electric compressor inverter unit connector.
6. Disconnect the high voltage electric compressor inverter unit connector (1).
-
The lock lever of the high voltage electric compressor inverter unit connector (1) must be moved from the locked position (A) to the unlocked
position (B) before pulling up to disconnect the high voltage electric compressor inverter unit connector (1) as shown.
CAUTION: Cap or wrap the connector with a suitable material such as vinyl tape to avoid the entry of any contaminants.
7. Remove the high voltage harness bracket from the electric compressor.
8. Remove the high-pressure flexible hose.
CAUTION: Cap or wrap the joint of the hose with a suitable material such as vinyl tape to avoid the entry of contaminants.