3. Ball joint axial end play
^
Apply an axial load of 490 N (50 kg-f, 111 lb-f) to ball stud using a dial gauge. Measure amount of stud movement, and then make sure that
the value is within the following specified range. Replace outer socket and inner socket if the measured value is outside the standard.
Assembly
Exploded View ST-15
Assembly
Assembly is in the reverse order of disassembly