nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Relays and Modules - HVAC > < Symptom Related Diagnostic Procedures|Page 12840
Page 1
background image

Refrigerant Pressure Sensor / Switch: Service and Repair

Removal and Installation for Refrigerant Pressure Sensor

1. Discharge the refrigerant. Refer to "HFC-134a (R-134a) Service Procedure".  See: Service and Repair
2. Disconnect the refrigerant pressure sensor connector and remove the refrigerant pressure sensor from condenser.

CAUTION:
-

Please be careful not to damage the condenser fins.

-

Apply compressor oil to the O-ring of the refrigerant pressure sensor when installing it.

Tightening torque : 9.8 - 11.7 N.m (1.0 - 1.2 kg-m, 7.3 - 8.6 ft-lb)

Relays and Modules - HVAC > < Symptom Related Diagnostic Procedures|Page 12840