Recall PB081/PB077 - A/C Condenser Fan Modification|Page 9278 > < Recall PB081/PB077 - A/C Condenser Fan Modification|Page 9276
Page 9
background image

Figure B-3

5. Before connecting to the vehicle battery, make sure the Fan Motor Tester is switched OFF. Switched to OFF

6. Connect the Fan Motor Tester and the Fluke 73 Digital Multimeter (using the fluke meter test leads) as follows (see Figure B-4):

-

Connect Fan Motor Tester harness connector to the condenser fan.

-

Connect Fan Motor Tester to the vehicle battery; Red clamp to + (positive) / Black clamp to - (negative).

-

Connect the Fluke 73 digital multimeter to the MOTOR VOLTAGE test ports on the Fan Motor Tester; V+ red probe to POS / COM black
probe to NEG.

Figure B-4

NOTE:  

When connected as above with the Fan Motor Tester switched OFF, the LED on the switch will illuminate green; this indicates the tester
has battery power.

Recall PB081/PB077 - A/C Condenser Fan Modification|Page 9278 > < Recall PB081/PB077 - A/C Condenser Fan Modification|Page 9276