Refrigerant Pressure Sensor / Switch: Service and Repair

Removal and Installation for Refrigerant Pressure Sensor

REMOVAL

1. Discharge the refrigerant. Refer to "HFC-134a (R-134a) Service Procedure".

2. Disconnect the refrigerant pressure sensor harness connector and remove the refrigerant pressure sensor from the condenser.

CAUTION:  Be careful not to damage the condenser fins.

INSTALLATION

Installation is in the reverse order of removal.
Refer to "Components".

CAUTION:

-

Be careful not to damage the condenser fins.

-

Apply compressor oil to the O-ring of the refrigerant pressure sensor for installation.

-

After charging refrigerant, check for leaks.