nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Electrical Specifications|Page 11344 > < Electrical Specifications|Page 11342
Page 1
background image

Alternator: Service and Repair

Removal and Installation - QR25DE Models

REMOVAL

1. Disconnect the negative battery terminal.
2. Remove the fan shroud. 
3. Remove the drive belt. 
4. Disconnect the generator harness connectors.
5. Remove generator mounting nut, using power tools.
6. Remove the generator upper bolt, using power tools.
7. Remove the generator.

GENERATOR PULLEY INSPECTION

Perform the following.

-

Make sure that the generator pulley does not rattle.

-

Make sure that the generator pulley nut is properly tightened.

Generator pulley nut : 118 Nm (12.0 kg-m, 87 ft-lb)

INSTALLATION

Installation is in the reverse order of removal.

-

Be sure the generator spacer is in place on the lower stud.

-

Install the generator and check tension of drive belt. Refer to "Tension Adjustment".

Terminal "1" nut : 10.8 Nm (1.1 kg-m, 8 ft-lb)

CAUTION:  Be sure to tighten terminal "1" nut carefully.

-

For this model, the power generation voltage variable control system that controls the power generation voltage of the generator has been adopted.
Therefore, the power generation voltage variable control system operation inspection should be performed after replacing the generator, and then
make sure that the system operates normally. Refer to SC-35, "Power Generation Variable Voltage Control System Inspection".  See: Testing and

Electrical Specifications|Page 11344 > < Electrical Specifications|Page 11342