nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Diagnostic Strategies|Page 7140 > < Electrical Specifications|Page 7137
Page 1
background image

Battery: Testing and Inspection
Diagnostic Strategies

Trouble Diagnosis With Battery/Starting/Charging System Tester

Trouble Diagnosis With Battery/Starting/Charging System Tester (BATTERY)

CAUTION: When working with batteries, always wear appropriate eye protection. 

NOTE:

To ensure a complete and thorough diagnosis, the battery, starter and generator test segments must be done as a set from start to finish. 
If battery surface charge is detected while testing, the tester will prompt you to turn on the headlights to remove the surface charge.
If necessary, the tester will prompt you to determine if the battery temperature is above or below 0 °C (32 °F). Choose the appropriate
selection by pressing the up or down arrow button, then press "ENTER" to make the selection.

1. Turn off all loads on the vehicle electrical system. Clean or repair as necessary.
2. Visually inspect the battery, battery terminals and cable ends with ignition switch in OFF position.

NOTE:

The contact surface between the battery terminals, cable ends and tester leads must be clean for a valid test. A poor connection will prevent
testing and a "CHECK CONNECTION" message will appear during the test procedures. If this occurs, clean the battery post and
terminals, reconnect them and restart the test.

3. Connect the red tester lead clamp to the positive battery terminal, and the black to the negative terminal.

4. The tester will turn on automatically. Using the arrow keys, select "IN-VEHICLE" on the tester and then press the "ENTER" key.

5. Locate the battery type and rating stamped or written on the top case of the battery to be tested.

NOTE:

The battery type and rating will have either of the following. 

Diagnostic Strategies|Page 7140 > < Electrical Specifications|Page 7137