Maxima V6-2960cc 3.0L DOHC (VE30DE) (1992)
Examine the oil feed hole in the tensioner and the oil jet in the cylinder head behind the tensioner for any metal chips or filings (see photos).
If any metal debris is found in the supply passage, go to Cylinder Head Oil Galley Cleaning Procedure (4).
NOTE:
Always wear appropriate skin and eye protection while performing these procedures.
Warranty Information
Note:
AP67AA is a straight-time operation. For R&I plugs and passage cleaning additional time over the recommended 1.0 hrs. may be claimed if required.