Maxima V6-2960cc 3.0L SOHC MFI (VG30E) (1990)
CAUTION:
a. Do not use standard charge method on a battery whose specific gravity is less than 1.100.
b. Set charging current to value specified see image Fig. 4. If charger is not capable of producing specified current value, set its charging
current as close to that value as possible.
c. Keep battery away from open flame while it is being charged.
d. When connecting charger, connect leads first, then turn on charger. Do not turn on charger first, as this may cause a spark.
e. If battery temperature rises above 60°C (140° F), stop charging. Always charge battery when its temperature is below 60°C (140° F).
C: Quick Charge