Battery: Testing and Inspection
Specific Gravity Check

SPECIFIC GRAVITY CHECK

Specific Gravity Check

1. Read hydrometer and thermometer indications at eye level.

Specific Gravity Check

-

When electrolyte level is too low, tilt battery case to raise it for easy measurement.

2. Convert into specific gravity at 20°C (68° F).
Example:

-

When electrolyte temperature is 35°C (95°F) and specific gravity of electrolyte is 1.230, converted specific gravity at 20°C (68°F) is 1.240.

-

When electrolyte temperature is 0°C (32°F) and specific gravity of electrolyte is 1.210, converted specific gravity at 20°C (68°F) is 1.196.