Maxima V6-3.5L (VQ35DE) (2007)
12. Remove the evaporator.
-
Remove the intake sensor.
CAUTION: Mark the mounting position of the intake sensor for installation.
INSTALLATION
Installation is in the reverse order of removal.
Expansion valve bolts: 2.9 - 5.0 N.m (0.29 - 0.51 kg-m, 26 - 44 in-lb)
CAUTION:
-
Replace the O-rings with new ones, then apply compressor oil to them when installing them.
-
After charging refrigerant, check for leaks. Refer to ATC-140, "Checking for Refrigerant Leaks". See: Testing and Inspection/Component
Tests and General Diagnostics/Checking for Refrigerant Leaks