nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Power Door Locks - Intermittently Lock By Themselves|Page 517 > < Power Door Locks - Intermittently Lock By Themselves
Page 2
background image

3.

If moisture or/and corrosion is found,

^

Proceed to step 6 and replace the door lock switch assembly and the LH door harness.

4.

If moisture or/and corrosion is not found, this bulletin does not cover the incident.

^

Refer to the ESM to further diagnose and repair the incident.

5.

Prepare the LH door harness connector (D1) to the (M4) SMJ as follows:

NOTE:

Refer to the Parts Information of this bulletin for the part numbers of replacement parts.

A.

Remove the door check link.

B.

Disconnect the LH door harness connector (D1).

C.

Clean the area of the A-Pillar where the LH door harness connector rubber boot (D1) makes contact. Ensure the area is free of dust or oil
film (see Figure 2).

D.

Apply dielectric grease to the electrical contacts of the new wire harness and main connector at the A-pillar (see Figure 3).

E.

Apply a 2 mm bead of RTV silicone sealant to the contact surface of the LH door harness connector rubber boot (see Figure 3).

6.

Connect the LH door harness connector (D1) onto the M4 SMJ connector.

7.

Tighten the bolt that fastens the harness connector rubber boot to 43 inch-lbs. using a 10 mm wrench.

8.

Wipe away any silicone sealant that becomes visible on the A-pillar.

9.

Apply dielectric grease to the brown connector for the new door lock switch harness (see Figure 1).

Power Door Locks - Intermittently Lock By Themselves|Page 517 > < Power Door Locks - Intermittently Lock By Themselves