Maxima GXE V6-3.0L (VQ30DE) (1999)
6. Pushing timing chain tensioner sleeve, apply a stopper pin so it does not return. Then remove the chain tensioner assembly.
7. Remove the 3 water pump fixing bolts. Secure a gap between water pump gear and timing chain, by turning crankshaft pulley 20° backwards.
8. Put M8 bolts to two M8-threaded holes out of 3 water pump fixing bolt holes.
9. Tighten M8 bolts by turning half turn alternately until they reach timing chain rear case.