nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 4143 > < Diagram Information and Instructions|Page 4141
Page 8
background image

1. Assemble a male terminal and approx. 10 cm (3.9 in) of wire. 

Use a male terminal which matches the female terminal.

2. Disconnect the suspected faulty connector and hold it terminal side up.

3. While holding the wire of the male terminal, try to insert the male terminal into the female terminal.

Do not force the male terminal into the female terminal with your hands.

4. While moving the connector, check whether the male terminal can be easily inserted or not.

^

If the male terminal can be easily inserted into the female terminal, replace the female terminal.

How to Probe Connectors

Connector damage and an intermittent connection can result from improperly probing of the connector during circuit checks. The probe of a Digital
Multimeter (DMM)
 may not correctly fit the connector cavity. To correctly probe the connector, follow the procedures below using a "T" pin. For the
best contact grasp the "T" pin using an alligator clip.

Probing From Harness Side

Diagram Information and Instructions|Page 4143 > < Diagram Information and Instructions|Page 4141