Maxima SE V6-3.0L (VQ30DE) (1998)
ECM TERMINALS AND REFERENCE VALUE
Specification data are reference values, and are measured between each terminal and (25) (ECCS ground).
ON BOARD DIAGNOSIS LOGIC
DIAGNOSTIC TROUBLE CODE CONFIRMATION PROCEDURE
NOTE: If "DIAGNOSTIC TROUBLE CODE CONFIRMATION PROCEDURE" has been previously conducted, always turn ignition switch "OFF"
and wait at least 5 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is more than 11V.
Without Scan Tools
1) Start engine and let it idle.
2) Wait at least 10 seconds.
3) Turn ignition switch "OFF", wait at least 5 seconds and then turn "ON".
4) Perform "Diagnostic Test Mode II (Self-diagnostic results)" with ECM.