Maxima SE V6-3.0L (VQ30DE) (1998)
CONSULT REFERENCE VALUE IN DATA MONITOR MODE
Specification data are reference values.
ECM TERMINALS AND REFERENCE VALUE
Specification data are reference values, and are measured between each terminal and (25) (ECCS ground).
ON BOARD DIAGNOSIS LOGIC
FAIL-SAFE MODE
When the ECM enters the fail-sate mode, the MIL illuminates.
DIAGNOSTIC TROUBLE CODE CONFIRMATION PROCEDURE
NOTE: If "DIAGNOSTIC TROUBLE CODE CONFIRMATION PROCEDURE" has been previously conducted, always turn ignition switch "OFF"
and wait at least 5 seconds before con- ducting the next test.
Without Scan Tools
1) Start engine and run it at least 2 seconds at idle speed.
2) Turn ignition switch "OFF", wait at least 5 seconds and then turn "ON".
3) Perform "Diagnostic Test Mode II (Self-diagnostic results)" with ECM.