Catalytic Converter: Service and Repair

Removal and Installation

CAUTION:

-

Always replace exhaust gaskets with new ones when reassembling.

-

With engine running, check all tube connections for exhaust gas leaks, and entire system for unusual noises.

-

Check to ensure that mounting brackets and mounting insulators are installed properly and free from undue stress. Improper installation could
result in excessive noise or vibration.

-

Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor;
use a new one.

-

Before installing a new heated oxygen sensor, clean exhaust system threads using heated oxygen sensor thread cleaner tool, J-43897-18 or
J-43897-12, and apply anti-seize lubricant.

-

Do not overtorque the heated oxygen sensor. Doing so may cause damage to the heated oxygen sensor, resulting in the MIL coming on.