Maxima SE V6-3.5L (VQ35) (2002)
Air Door Actuator / Motor: Adjustments
Intake Door Motor
Automatic
*
Automatic Air Conditioning System *
CONTROL LINKAGE ADJUSTMENT
Intake Door
1. Install intake door motor on intake unit and connect it to main harness.
2. Set up code No. in Self-diagnosis STEP 4.
3. Make sure intake door operates properly when changing from code No. 41 to 46 by pushing DEF switch.
Manual
*
Manual Air Conditioning System *
CONTROL LINKAGE ADJUSTMENT
Intake Door Motor
1. Install intake door motor on blower and intake unit.
Ensure that the intake door motor lever is fitted into the slit portion of intake door link.
2. Connect the intake door motor harness connector.
3. Turn ignition switch to ON.
4. Check that intake door operates properly when RECIRCULATION switch is turned ON and OFF.