Maxima SE V6-3.5L (VQ35) (2002)
Refrigerant: Testing and Inspection
Checking For Leaks Using Electronic Refrigerant Leak Detector
Electronic Refrigerant Leak Detector
PRECAUTIONS FOR HANDLING LEAK DETECTOR
When performing a refrigerant leak check, use a J-41995 A/C leak detector or equivalent. Ensure that the instrument is calibrated and set properly per
the operating instructions.
The leak detector is a delicate device. In order to use the leak detector properly, read the operating instructions and perform any specified maintenance.
1. Position probe approximately 5 mm (3/16 in) away from point to be checked.
2. When testing, circle each fitting completely with probe.
3. Move probe along component approximately 25 to 50 mm (1 to 2 in)/sec.
CHECKING PROCEDURE