Maxima Wagon V6-2960cc 3.0L SOHC MFI (VG30E) (1986)
Control Assembly: Testing and Inspection
Potentio Temperature Control (PTC) Testing
POTENTIO TEMPERATURE CONTROL (PTC)
^ Ensure that there is voltage between auto amp. side terminal at auto air conditioner harness and body ground, using the table below.
Ignition switch: ON
Temp. lever: 20-30°C (65-85°F)
PTC position °C (°F)
Voltage (Volts)
20 (65)
1.75
30 (85)
1.02