Maxima Wagon V6-2960cc 3.0L SOHC MFI (VG30E) (1986)
Solar Sensor: Testing and Inspection
Sunload Sensor - Testing
SUN LOAD SENSOR
1. After disconnecting sunload sensor amp. connector, ensure that there is current between terminals 685 and 653 on vehicle harness side.
2. Check operation of pointer of millimeter (1 mA level) when sunload is applied to the sensor and then after shielding the sensor with a hand.