Refrigerant Pressure Sensor / Switch: Service and Repair

Removal and Installation of Refrigerant Pressure Sensor

REMOVAL

1. Remove the condenser. Refer to "Removal and Installation of Condenser".
2. Remove the refrigerant pressure sensor from condenser.

CAUTION:  When working, be careful not to damage the condenser fins.

INSTALLATION

Installation is basically the reverse order of removal.

CAUTION:  Apply compressor oil to the O-ring of the refrigerant pressure sensor when installing it.

Refrigerant pressure sensor
Tightening torque : 9.9 - 11.7 Nm (1.0 - 1.2 kg-m, 87 - 104 in-lb)