Murano FWD V6-3.5L (VQ35) (2004)
procedure.
a. Remove quick connector cap from quick connector.
b. Disconnect quick connector from centralized under-floor piping.
^
Disconnect the quick connectors as follows.
- Pick out retainer tab by hand and remove.
- If connector and centralized under-floor piping connection are stuck, push and pull several times until they start to move. Then
disconnect them by pulling.
CAUTION:
^
Keep parts away from heat source. Especially, be careful when welding is performed around them.
^
Do not expose parts to battery electrolyte or other acids.
^
Do not bend or twist connection between quick connector and fuel hose during installation/removal.
^
Do not remove retainer.
^
When replacing centralized under-floor piping, always replace retainer with a new one.
^
When replacing retainer, use same color retainer as was originally installed.
Retainer color: Green