Murano FWD V6-3.5L (VQ35) (2004)
4. Select the desired part to be diagnosed on the "SELECT DIAG MODE" screen.
SELF-DIAG RESULTS
Operation Procedure
1. Touch "SELF-DIAG RESULTS" on "SELECT DIAG MODE" screen.
2. Check display content in self-diagnostic results.
Display Item List
NOTE: The details for display of the period are as follows:
-
CRNT: Error currently detected with IPDM E/R.
-
PAST: Error detected in the past and memorized with IPDM E/R.
DATA MONITOR
Operation Procedure
1. Touch "DATA MONITOR" on "SELECT MONITOR ITEM " screen.
2. Touch "ALL SIGNALS", "MAIN SIGNALS" or "SELECT FROM MENU" on the "DATA MONITOR" screen.
3. Touch "START".
4. Touch the required monitoring item on "SELECT ITEM MENU". In "ALL SIGNALS", all items are monitored. In "MAIN SIGNALS",
predetermined items are monitored.
5. Touch "RECORD" while monitoring to record the status of the item being monitored. To stop recording, touch "STOP".