Murano FWD V6-3.5L (VQ35) (2004)
7. Remove the power window motor mounting bolts, and remove the regulator from the panel.
8. Disconnect the connector for the regulator assembly.
INSTALLATION
Install in the reverse order of removal.
INSPECTION AFTER REMOVAL
Check the regulator assembly for the following items. If a malfunction is detected, replace or grease it.
-
Wire wear
-
Regulator deformation
-
Grease condition for each sliding part
The arrows in the figure show the application points of the grease "Dow Corning Moly Coat SK 623" or equivalent.