Audible Warning Device: Reading and Clearing Diagnostic Trouble Codes

CONSULT-II Basic Operation Procedure

CONSULT-II BASIC OPERATION PROCEDURE

CAUTION:  If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending
on control unit which carry out CAN communication.

1. With the ignition switch OFF, connect "CONSULT-II" and "CONSULT-II CONVERTER" to the data link connector, and then turn the ignition

switch ON.

2. Touch "START (NISSAN BASED VHCL)".

3. Touch "BCM" on "SELECT SYSTEM" screen. If "BCM" is not indicated, go to GI-39, "CONSULT-II Data Link Connector (DLC) Circuit".  

See: Diagrams/Electrical Diagrams/Powertrain Management/Computers and Control Systems/Data Link Connector/Schematic