nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 12653 > < Diagram Information and Instructions|Page 12651
Page 16
background image

Checking Equipment

CAUTION:

-

If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on 
control unit which carry out CAN communication.

-

If CONSULT-II CONVERTER is not connected with CONSULT-II, vehicle occur the "FAIL SAFE MODE" which is "LIGHT UP the HEAD
LIGHT" and/or "COOLING FAN ROTATING" when CONSULT-II is started.

-

Previous CONSULT-II "I" and "Y" DLC-I and DLC-II cables should NOT be used anymore because their DDL connector pins can be damaged
during cable swapping.

NOTE:

-

The CONSULT-II must be used in conjunction with a program card. CONSULT-II does not require loading (Initialization) procedure.

-

Be sure the CONSULT-II is turned off before installing or removing a program card.

CONSULT-II Start Procedure

NOTE:  Turning ignition switch off when performing CAN diagnosis could cause CAN memory to be erased.

1. Connect CONSULT-II and CONSULT-II CONVERTER to the data link connector.

2. If necessary, turn on the ignition switch.
3. Touch "START (NISSAN BASED VHCL)" or System Shortcut key (eg: ENGINE) on the screen.

Diagram Information and Instructions|Page 12653 > < Diagram Information and Instructions|Page 12651