Murano FWD V6-3.5L (VQ35DE) (2006)
Installation
Install in the reverse order of removal.
Inspection after Removal
Check the regulator assembly for the following items. If a malfunction is detected, replace or grease it.
-
Wire wear
-
Regulator deformation
-
Grease condition for each sliding part
The arrows in the figure show the application points of the multi-purpose grease.
Inspection after Installation
SETTING OF LIMIT SWITCH
If any of the following work has been done, reset the limit switch (integrated in the motor).
-
Removal and installation of the regulator.
-
Removal and installation of the motor from the regulator.
-
Operate the regulators as a unit.
-
Removal and installation of the glass.
-
Removal and installation of the glass run.
Resetting
After installing each component to the vehicle, follow the steps below.
1. Remove the motor from regulator.
2. Connect the connector. Rotate the motor unit with power window switch for more than 5 sec in glass raising direction.
3. Install motor to regulator.
4. Raise glass to the top position.
CAUTION: Do not use Auto switch to raise the glass to the top position.
FITTING INSPECTION
-
Make sure the glass is securely fit into the glass run groove.
-
Lower the glass slightly [approx. 10 to 20 mm (0.39 to 0.79 in)] and make sure the clearance to the sash is parallel. If the clearance between the
glass and sash is not parallel, loosen the regulator mounting bolts, guide rail mounting bolts, and glass and guide rail mounting bolts to correct the
glass position.