nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Automatic Air Conditioner|Page 10097 > < Automatic Air Conditioner|Page 10095
Page 18
background image

Apply 12 volts to terminal 1 and ground to terminal 2 and ensure that the blower motor rotates freely and quietly.

Rear Blower Motor Resistor

Check continuity between terminals. There will be resistance, but there should not be an open or short between any two terminals.

Automatic Air Conditioner|Page 10097 > < Automatic Air Conditioner|Page 10095