nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Engine Controls - Seized O2 Sensor Removal Procedure|Page 1375 > < Engine Controls - Seized O2 Sensor Removal Procedure|Page 1373
Page 1
background image

Oxygen Sensor: Technical Service Bulletins
Engine Controls - Oxygen Sensor Description & New Torque

Models

All Models (1982-1987)

Section

Emission Control

Classification

EC86-010

Bulletin No.

TS86-128

Date

July 11, 1986

EXHAUST GAS SENSORS, ALL MODELS

SERVICE INFORMATION

Starting with the 1986 Model Year, two types of exhaust gas sensors have been used on Nissan vehicles. In addition to the previously used Zirconia type
sensor, some 1986 and 1987 vehicles are now being manufactured with Titania type sensors. This bulletin contains a description of these sensors and a
model application chart for your reference.

In addition, the tightening torque for exhaust gas sensors has been standardized. This revised torque information follows the appropriate model
application chart. Please make note of the new torque by hand in the Tightening Torque Table of the EF&EC S.D.S. Section of the appropriate model
Service Manual, if necessary.

I.

ZIRCONIA TYPE EXHAUST GAS SENSOR The exhaust gas sensor, which is placed into the exhaust manifold, monitors the mount of oxygen
in the exhaust gas. The sensor has a closed-end tube made of ceramic zirconia. The outer surface of the tube is exposed to exhaust gas, and the
inner surface to atmosphere. The zirconia of the tube compares the oxygen density of exhaust gas with that of atmosphere, and generates
electricity. In order to improve generating power of the zirconia, its tube is coated with platinum. The voltage is approximately 1V when the
mixture ratio is richer than the ideal air-fuel ratio, and approximately OV when leaner. The radical change from 1V to OV occurs near the ideal
mixture ratio. In this way, the exhaust gas sensor detects the amount of oxygen in the exhaust gas and sends the signal of approximately 1V or OV
to the E.C.U. On 1984-1985 300ZX and 1985-1986 Maxima models, with VG30 engines a ceramic heater was employed to ensure the stable
performance of the sensor.

Make note of this new torque information in the Tightening Torque Table, EF&EC Section of these model Service Manuals.

Engine Controls - Seized O2 Sensor Removal Procedure|Page 1375 > < Engine Controls - Seized O2 Sensor Removal Procedure|Page 1373