48,000 km (30,000 miles) service

Exhaust gas sensor should be checked after every 48,000 km (30,000 miles) of operation. The exhaust gas sensor warning lamp will come on at 48,000
km (30,000 miles) to indicate that sensor should be inspected. After the first inspection, disconnect warning lamp harness connector.

Checking Exhaust Gas Sensor (U11) Maxima

ENGINE MAINTENANCE

Checking Exhaust Gas Sensor (U11)

FOR U.S.A. MODELS

Every 30,000 miles (48,000 km) service

Exhaust gas sensor should be checked after every 30,000 miles (48,000 km) of operation. After vehicle has been operated for 30,000 miles (48,000 km)
and for 60,000 miles (96,000 km) exhaust gas sensor warning lamp will come on to indicate that sensor should be inspected. After inspection, reset
warning lamp hold relay so that warning lamp will come on after the next 30,000 miles (48,000 km).