Pulsar L4-1809cc 1.8L DOHC (CA18DE) (1988)
Air Door Cable: Service and Repair
Air Control
1.
Set air control lever at DEF position.
2.
Move link lever toward firewall.
3.
Connect air control cable to link lever and clamp cable.
4.
Ensure that knob moves smoothly.