nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Hose/Line HVAC|Service Precautions|Page 9766 > < High Pressure Safety Valve HVAC|Description and Operation
Page 1
background image

Hose/Line HVAC: Service Precautions

WARNING:  MAKE SURE ALL REFRIGERANT IS DISCHARGED INTO THE RECYCLING EQUIPMENT AND THE PRESSURE IN
THE SYSTEM IS LESS THAN ATMOSPHERIC PRESSURE. THEN GRADUALLY LOOSEN THE DISCHARGE SIDE HOSE FITTING
AND REMOVE IT.

CAUTION:  Refrigerant connections in some systems use different O-ring configurations. Do not confuse O-rings since they are not interchangeable. If
a wrong O-ring is installed, refrigerant will leak at, or around, the connection.

CAUTION:  When replacing or cleaning refrigerant cycle components, observe the following.

-

When the compressor is removed, store it in the same position as it is when mounted on the car. Failure to do so will cause lubricant to enter the
low pressure chamber.

-

When connecting tubes, always use a torque wrench and a back-up wrench.

-

After disconnecting tubes, immediately plug all openings to prevent entry of dirt and moisture.

-

When installing an air conditioner in the vehicle, connect the pipes as the final stage of the operation. Do not remove the seal caps of pipes and
other components until just before required for connection.

-

Allow components stored in cool areas to warm to working area temperature before removing seal caps. This prevents condensation from forming
inside A/C components.

-

Thoroughly remove moisture from the refrigeration system before charging the refrigerant.

-

Always replace used O-rings.

-

When connecting tube, apply lubricant to circle of the O-rings shown in illustration. Be careful not to apply lubricant to threaded portion.
Lubricant name: Nissan A/C System Oil Type F 
Part number: KLH00-PAGS0

-

O-ring must be closely attached to dented portion of tube.

-

When replacing the O-ring, be careful not to damage O-ring and tube.

-

Connect tube until you hear it click, then tighten the nut or bolt by hand until snug. Make sure that the O-ring is installed to tube correctly.

-

After connecting line, conduct leak test and make sure that there is no leakage from connections. When the gas leaking point is found, disconnect
that line and replace the O-ring. Then tighten connections of seal seat to the specified torque.

Hose/Line HVAC|Service Precautions|Page 9766 > < High Pressure Safety Valve HVAC|Description and Operation