background image

Hose/Line HVAC: Description and Operation

A new type refrigerant connection has been introduced to all refrigerant lines except the following portion.

-

Front evaporator core connections.

FEATURES OF NEW TYPE REFRIGERANT CONNECTION 

-

The O-ring is relocated in a groove for proper installation. This eliminates the chance of the O-ring being caught in, or damaged by, the mating
part. The sealing direction of the O-ring is now set vertically in relation to the contacting surface of the mating part to improve sealing
characteristics.

-

The reaction force of the O-ring will not occur in the direction that causes the joint to pull out, thereby facilitating piping connections.

SPRING LOCK COUPLING 

The spring lock coupling is a refrigerant line coupling held together by a garter spring inside a circular cage. When the coupling is connected, the
flared end of the female fitting slips behind the garter spring inside the cage of the male fitting. The garter spring and cage prevent the flared end
of the female fitting from pulling out of the cage.
Three green O-rings are used to seal the three halves of the coupling. These O-rings are made of special material and must be replaced with an
O-ring made of the same material. The O-rings normally used in refrigerant system connections are not the same material and should not be used
with the spring lock coupling. Use only the specified O-ring for the spring lock coupling.