Quest Minivan XE V6-2960cc 3.0L SOHC MFI (VG30E) (1998)
Keyless Entry: Description and Operation
Power is supplied at all times:
^
from 30 A fusible link (letter [a], located in the fuse and fusible link box)
^
to circuit breaker-1 terminal (1)
^
through circuit breaker-1 terminal (2)
^
to smart entrance control unit terminal (3).
Power is supplied at all times:
^
from 7.5 A fuse (No. [41], located in the fuse and fusible link box)
^
to smart entrance control unit terminal (9).
Power is supplied at all times:
^
from 15 A fuse (No. [44], located in the fuse and fusible link box)
^
to horn relay terminals (2) and (3).
Power is supplied at all times:
^
to tail lamp relay terminals (2) and (3).
Ground is supplied:
^
to smart entrance control unit terminals (1), (20) and (54)
^
through body grounds M5, M78 and M123.
INPUTS
When the ignition key is inserted in ignition key cylinder, ground is supplied:
^
through key switch terminal (1)
^
to smart entrance control unit terminal (14).
When the front door LH is open, ground is supplied:
^
to smart entrance control unit terminal (5)
^
through front door switch LH terminal (2).
When the front door RH is open, ground is supplied:
^
to smart entrance control unit terminal (4)
^
through front door switch RH terminal (1).
When the sliding door is open ground is supplied:
^
to smart entrance control unit terminal (30)
^
through sliding door switch terminal (1).
When the tailgate is open, ground is supplied:
^
to smart entrance control unit terminal (29)
^
through back door latch switch terminal (1) (with normal glass), or terminal (2) (with glass hatch)
^
to back door latch switch terminal (2) (with normal glass), or terminal (1) (with glass hatch)
^
through body ground B104.
When the front door lock actuator LH (door unlock sensor) is UNLOCKED, ground is supplied:
^
to smart entrance control unit terminal (28)
^
through front door lock actuator LH (door unlock sensor) terminal (3)
^
to front door lock actuator LH (door unlock sensor) terminal (4)
^
through body grounds M5, M78 and M123.
When the front door lock actuator RH (door unlock sensor) is UNLOCKED, ground is supplied:
^
to smart entrance control unit terminal (27)
^
through front door lock actuator RH (door unlock sensor) terminal (3)
^
to front door lock actuator RH (door unlock sensor) terminal (4)
^
through body grounds M5, M78 and M123.
When the sliding door lock actuator (door unlock sensor) is UNLOCKED, a ground signal is supplied:
^
to sliding door control unit terminal (1)
^
through sliding door lock actuator (door unlock sensor) terminal (4)
^
to sliding door lock actuator (door unlock sensor) terminal (3)
^
through sliding door control unit terminal (8).
A sliding door status signal is supplied:
^
to smart entrance control unit terminal (10)