nissan Workshop Repair Guides

Nissan and Datsun Workshop Service and Repair Manuals

Power Locks & Alarm - Erratic Operation|Page 9779 > < Power Locks & Alarm - Erratic Operation
Page 2
background image

2.

Remove the trim panel next to the Smart Entrance Control Unit (SECU) See figure 1 for SECU location.

3.

At connector M46 of the SECU, back probe pin terminal 27 (Unlock Sensor RH, G/Y wire) and pin terminal 28 (Unlock Sensor LH, R/Y wire)
using a suitable tool. Refer to Figure 2 below for pin locations. Leave connector M46 connected to the SEGU.

4.

Use CONSULT-II to monitor voltage on connector M46 pin terminals 27 & 28:

NOTE:

Connect CONSULT-II to AC power if necessary, depending on CONSULT-II's state of charge.

a.

Turn CONSULT-II "ON."

b.

Touch "SUB-MODE."

c.

Touch "MEASUREMENT."

d.

Touch "Voltage (Dual)."

e.

Connect the Red CONSULT-II lead to the back probe tool on M46 pin terminal 27 (G/Y wire).

f.

Connect the Blue CONSULT-II lead to the back probe tool on M46 pin terminal 28 (R/Y wire).

g.

Connect the ground lead of CONSULT-II to a suitable ground.

5.

Observe the voltage readings on the CONSULT-II screen:

^

It the voltage reading is below 0.8v, continue testing by proceeding to step 6.

^

If the voltage reading is above 0.8v, proceed to the "Lock Rod Operation and Adjustment Test" in this bulletin.

6.

Perform the following actions:

Power Locks & Alarm - Erratic Operation|Page 9779 > < Power Locks & Alarm - Erratic Operation